Call 08047309127 79% Response Rate

Send Enquiry

our range

Schneider Mccb

Our range of products include cvs 800f schneider mccb and 250 amp schneider mccb.

CVS 800F Schneider MCCB

  • CVS 800F Schneider MCCB
  • CVS 800F Schneider MCCB
  • CVS 800F Schneider MCCB
  • CVS 800F Schneider MCCB
CVS 800F Schneider MCCB
Get Best Quote
Rs 1,25,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Product Brochure

Current Rating800A
No. of Poles3 Pole
Breaking Capacity50KA
BrandSchneider
CertificationCE Certified
Voltage415V
Trip TypeThermal Magnetic
MaterialABS
Frequency50Hz
SCHNEIDER MCCB CVS 800F, LV580300, LV580302, LV580301, LV580303
EasyPact CVS 800A MCCBs are available in 3P/4P version with 35/50kA
breaking performances with Ics = 100% Icu. EasyPact CVS comes with host of
features including adjustable overload, short circuit setting, line load reversibility.
b Ics=100% Icu.
b Adjustable over load setting (0.8 to 1 x In)
b Adjustable short circuit setting for individual phase (3.5 to 10 In)
b Line load reversibility

View Complete details

Yes! I am Interested Request a call back

250 Amp Schneider MCCB

  • 250 Amp Schneider MCCB
  • 250 Amp Schneider MCCB
250 Amp Schneider MCCB
Get Best Quote
Rs 50,000  / PiecePrice on Request

Minimum Order Quantity: 1 Piece

Product Brochure

No. of PolesTriple Pole
Breaking Capacity50 KA
Rated Current250A
BrandSchneider
CertificationCE Certified
Voltage415V
Model Name/NumberLV431403X62A250
Trip TypeThermal Magnetic
Mounting StyleNUT MOUNTING
Frequency50Hz
Schneider Electric Compact Nsx Mccb,
Schneider Molded Case Circuit Breakers,
Schneider Mccb Dealer,

MCCB 250 AMP 3POLE 50 KA MICROLOGIC 6.2, NSX 250, LV431403X62A250, WITH ADJUSTABLE OVERLOAD, ADJUSTABLE SHORT CIRCUIT,  ADJUSTABLE EMBEDED EARTH FAULT, INSTANTANEOUS & ADJUSTABLE NEUTRAL PROTECTION. MAKE - SCHNEIDER
SERIES - NSX 250
AMP - 250 AMP
TRIPPING UNIT - MICROLOGIC 6A/6.2
CAT NO - LV431403X62A250
MAKE - SCHNEIDER

¬ Protection type LSIGN ( Long-Time, Short-Time, Instantaneous, Ground Fault, Neutral)
¬ Current measurements (Phase & neutral, Average, Highest of phases, Ground
fault current, Maximeter / Minimeter, Current unbalance between phases)
¬ Adjustable overload from Ir 0.36 to 1 x In and tr = 0.5 - 16 s
¬ Adjustable short circuit from Isd 1.5 - 10 x Ir and tsd I2tON/OFF 0.1 - 0.4s
¬ Adjustable earth fault 0.4 - 1 x In (for In=40A) & 0.2 - 1 x In (for In>40A) and tg
I2tON/OFF 0.1 - 0.4s